Equipment Overview
The furnace is placed in a large atmosphere chamber, and the bottom of the furnace is mounted on a special trolley for easy loading and unloading of specimens. The temperature is controlled by a programmable temperature controller and gas is automatically introduced by a time signal function, and humidifying gas can also be introduced by a selector switch.

forte
- The airtight structure allows for rapid gas displacement and easy maintenance of various gas atmospheres.
- It is equipped with highly reliable temperature control devices and is easy to operate.
- The safety function is fully equipped for unattended use.
- High-quality alumina fiberboard insulation provides excellent thermal insulation and saves power consumption.
Bogie-Type Atmosphere Furnace Specifications | |
Normal operating temperature | 1750℃ in air 1400℃ in atmosphere |
Maximum temperature | 1750℃ in air 1500℃ in atmosphere |
Temperature rise time | 5 hours (at 1750°C, no load, in air) |
Furnace dimensions | W450×H550×L1520 mm |
Heating element | Molybdenum disilicide ( MoSi2 ) |
Atmosphere | N2, N2 + H2 (~3%), humidified |
Vacuum gas replacement | Oil rotary pump, diffusion pump (exhaust), automatic displacement |
Ancillary equipment | Hot water cooling tank, humidifying tank, dew point meter, heater to prevent condensation, high vacuum exhaust system Pyrani vacuum gauge, ionization vacuum gauge, pressure switch, |
Control unit | Self-supporting panel |
Heater capacity | Single phase 140A 22.4kW 2 circuits + 28.0kW 1 circuit |
Primary power supply | AC200V three-phase 98kVA |