Equipment Overview
This is an electric furnace with a condenser heating system that allows rapid heating and cooling of samples at ultra-high temperatures with simple operation, as well as high-temperature observation in a vacuum, gas atmosphere, or air.

Features
- Rapid heating and cooling to ultra-high temperatures
 Gold-plated mirror finish inside the furnace chamber and airtight structure.
- Heating in a clean atmosphere
 No particle-producing insulation materials in the furnace
- Observation of samples at high temperatures
 Observation of high temperature behavior of workpieces even at temperatures above 1500°C
- Real-time temperature control
 Captures workpiece temperature and feeds it back to temperature control Real-time temperature control (PV value = sample temperature)
- Energy-saving and space-saving.
 Set on a desk, no extra space required
option
- Atmosphere control unit
 Easy vacuum evacuation, gas displacement, and gas flow
- High-temperature observation unit (x20 to x850 depending on application)
 Set of zoom lens and stage for high temperature observation
- Dedicated temperature control unit
 PID continuous control method with programmed controller
- Dedicated Application Software
 Simultaneous recording of high temperature images captured by a video camera, temperature and time is possible.


Temperature Control Unit
- Compact design
- Current feedback type PID continuous control method with program controller and thyristor
- With automatic and manual operation switching
- Built-in dedicated alarm circuit
Main applications
| High-Speed Heat Treatment | High-speed heat treatment, thermal cycling, and thermal shock testing of various metallic materials | 
| High temperature observation | High temperature in-situ observation, high temperature behavior, reaction observation Contact angle, wettability measurement, | 


| Super Image Furnace Specifications | ||
| Model | SVF-QP1-4 | SVF-QP2-6 | 
| Maximum temperature | 1700°C | |
| Furnace Structure | 4-elliptical shared light-concentration tube furnace | |
| Atmosphere * | Atmosphere, vacuum (up to 1200°C), gas atmosphere | |
| Sample Exchange Port | 52 x 40 mm | 100×44mm | 
| Heating length | 110mm | 210mm | 
| Equal heating zone | 10-15mm dia. x L35mm | 10-15mm dia. x L100mm | 
| Lamps used | 1kW x 4 | 1.5kW x 4 | 
| Cooling water | 4L /min or more | 6L /min or more | 
| Vacuum exhaust port | 1/4 Swagelok (Rear) | NW16 (Side: OP) | 
| Thermocouple airtight port | 2 locations on the sample exchange port | |
| Specimen holder * | Platinum W10 x L32 x H4mm | To be discussed separately | 
| Equipment power supply | 1φ 200V 25A | 1φ 200V 35A | 
| Temperature control method | PID continuous control with program controller Manual/automatic changeover, ammeter, various switches, safety circuit | |
*Vacuum, gas atmosphere and sample holder are optional.