Glass melting furnace for research and development GVF-2025

Equipment Overview

This electric furnace is designed for melting and vitrifying glass materials and can be used for research and development of “new glass”. The furnace body is split in two and the furnace bottom can be raised and lowered for easy material loading and crucible replacement. A crucible of 1 to 2 L capacity is set inside the split furnace, and after melting and stirring the glass materials, molten glass is discharged from the bottom of the furnace. The discharged glass can be used for primary frit, plucking, or pouring into molds, depending on the purpose of the operation.

Glass melting furnace GVF-2025

feature

  • Dry grinding method eliminates the need to dry samples (optional)
  • Viscosity can be adjusted during molding by installing a temperature-settable auxiliary furnace in the glass outflow section (optional).
  • Optional plunger mechanism allows for optional outflow adjustment (optional).
  • Variable stirring mechanism allows degassing and defoaming during glass melting for homogenization and clarification process (optional)

*We can also handle press forming, wire drawing (wire diameter control, cutting), etc.

option

Optional mechanisms can be installed to suit each purpose.

  • Auxiliary furnace (platinum heater at nozzle)
  • Direct current electric heating
  • platinum crucible
  • Dry quenching roller crushers, etc.
  • plunger mechanism
  • Platinum stirrer
  • Material feeder
SpecificationsGVF-2025
  Melting furnace Nozzle heating chamber (option) Direct current heating (option)
 Heating chamber dimensions 250×250mm φ42×H100mm φ15.5×φ14.5×H145mm
 Furnace opening dimensions 200mm dia. 40mm dia. 20mm dia.
 Furnace bottom dimensions φ185mm with elevation —Furnace bottom size — with elevation
 Max. temperature 1700°C 1500°C — — — normal temperature
 Normal temperature 1650°C 1450°C —Heater capacity
 Heater capacity 6.0kW 0.5kW 1.5kW
 Thermocouple JIS-B JIS-B JIS-B
 Atmosphere Atmosphere Atmosphere Atmosphere
 Heating element Molybdenum disilicide Platinum Heater Platinum tubes
 Control method PID control PID control —PID control
 Platinum crucible 130mm dia. x 150mm H —PID control — PID control