Low Oxygen Oven

Equipment Overview

  • Inert gas (N2 or Ar) is introduced into the furnace to perform drying and heat treatment under program control.
  • Oxidation-resistant samples can be heat-treated at low oxygen concentrations of 20 PPM to 1000 PPM (0.1%).

Main applications

Heat treatment and degreasing of products. Prevention of oxidation of metal products, etc. Hardening of resin materials, etc. Heat treatment of electronic parts, etc.

Low Oxygen Oven
Low oxygen heat treatment
  • Low oxygen atmosphere specification with inert gas (N2 or Ar). This is ideal for customers who need to control oxygen concentration.
    Ideal for specimens that require heat treatment while minimizing oxidation. Our original design allows for improved sealing and an oxygen concentration of 20 PPM.
  • Nitrogen gas is introduced into the system, so heat treatment can be performed in a clean environment.
  • Inert gas (N2 or Ar) can also be used in conjunction with the temperature program.
  • Explosion-proof specifications are also available. (with explosion vent, etc.)
  • Water-cooled forced cooling system (optional) is also available to speed up the descent time.
  • Even when operating at 600°C, the safe design with a surface temperature of 50°C or less ensures safe use.
Equipment Specifications
Item Description
Product name Hypoxic Oven
Method Hot air circulation method
Temperature range RT+30°C to +300°C
Inner dimensions of oven W1500 x H1500 x D1500 mm
Outer dimensions W3000× H2350× D2000 mm (not including protrusions)

We also have other types of furnaces such as “800 mm square, Max 600°C, 20 PPM” and “W2000 x H1300 x H1300, Max 500°C, 20 PPM”. We also have a variety of other types of products.

We will design and manufacture according to the conditions of use.


Large drying furnace (Nitrogen flow specification)

Equipment Overview

  • Nitrogen is introduced into the furnace to perform drying and heat treatment under program control. Specimens that do not like oxidation can be heat-treated in low oxygen concentration.
  • The spacious furnace is equipped with sample fixtures.

Main applications

DVD, CD heat treatment, capacitor heat treatment, epoxy resin curing

Nitrogen flow drying furnace

Features

  • Low oxygen atmosphere specification with nitrogen replacement
  • Ideal for heat-treating samples with minimal oxidation.
  • Gas inlet specifications allow heat treatment in a clean environment.
Equipment Specifications
Item Description
Product name Large drying furnace (nitrogen flow)
Method Hot air circulation method
Temperature range RT+30°C to +200°C
Inner dimensions of furnace W1500×H1200×D700 mm
Outer dimensions W2000×H1800×D1200 mm (without protrusions)

These are basic specifications. We will design and manufacture according to your company’s conditions of use.

Scroll to Top