Heat treatment furnace with fixed ventilation and forced exhaust

Equipment Overview

  • This is a forced exhaust type heat treatment furnace with ample power for heat treatment while ventilating.
  • During heat treatment, a certain amount of gas or binder can be ventilated from the sample.
  • When gases are generated from the sample, heat treatment can be performed while discharging the gases.
  • The exhaust blower can be operated during the temperature drop to introduce outside air to shorten the temperature drop time.

Main applications

Capacitor de-moistening, capacitor degreasing, paint drying, heat treatment of rubber, heat treatment of fluorocarbon coatings

Fixed Ventilation Heat Treatment Furnace
Forced exhaust heat treatment furnace

forte

  • Equipped with sufficient heater capacity.
  • Heat treatment can be performed while ventilating, and unwanted gases are removed from the tank.
  • The temperature drop time can be shortened, thus reducing process time.
Equipment Specifications
Item Description
 Product name  Furnace with fixed ventilation and forced exhaust
 Method  Hot air circulation method
 Temperature range  RT+40°C to +450°C
 Inner dimensions of furnace  W600×H1000×D800 mm
 Outside dimensions  W1400 x H2200 x D1200 mm

Full-discharge dryer

Equipment Overview

  • Equipped with sufficient heater capacity for heat treatment while exhausting all air.
  • Because it is not a hot air circulation type but a total exhaust type, any gas or binder generated from the specimen is exhausted in one direction. Therefore, binder generated from the sample does not adhere to the sample or to the heater.

Main applications

Heat treatment of rubber, heat treatment of fluorine coatings, etc., heat treatment of specimens that generate solvent gas

forte

  • Special construction prevents hot air passing through the furnace from contacting the heater.
  • Since hot air does not circulate inside the furnace, binder and other materials do not re-attach to the sample.
  • Even if flammable gases are generated from the sample, they do not come in contact with the heating heater because of the total exhaust system, thus enhancing safety.
  • Compared to the hot-air circulation type, the total exhaust type requires a larger heater capacity, resulting in higher electricity costs.
Equipment Specifications
Item Description
 Product name  Total Exhaust Dryer
 Method  Total exhaust system (hot air one-pass type)
 Temperature range  RT+50°C to +160°C
 Inner dimensions of furnace  W900×H1500×D1000 mm
 Outside dimensions  W2000 x H2300 x D1300 mm

These are basic specifications. We will design and manufacture according to your company’s conditions of use.

Scroll to Top