Continuous annealing system (clean room compatible)
Equipment Overview This system is a hot-air circulation curing furnace with resistance heating for clean rooms. Basic Specifications Temperature Range Max. 150°C, Normal 120°C Temperature distribution ± 5°C Temperature rise time Approx. 60 minutes to 120°C (no load) Cooling time Within 30 seconds from 110°C to 80°C Cleanliness (inside furnace) Class 100 (with heat-resistant HEPA […]
Continuous annealing system (clean room compatible) read more »